Residential wastewater treatment plants Aquatec VFL - AT 6 - AT 20

VFL

AT6 - AT20 residential wastewater treatment plants were invented to purify sewage water for detached houses. 

Wastewater treatment plants of the AT 6 to AT 20 series are solutions and bring benefits for every household:

  • Clean water directly at source of pollution
  • Low operating costs of wastewater treatment unit
  • Operation up to 8 times cheaper compared to the cesspool
  • High quality purified water
  • Reuse of purified water
  • Quiet, odorless
  • Meets the prescribed EN 12566-3 standard

Purified waste water can be discharged into surface or underground water, recycle it by using for irrigation of lawns and ornamental greenery or use it for technical purposes after filtration.

   
wastewater treatment plants Aquatec VFL Design of accurate
WWTP solution
wastewater treatment plants Aquatec VFL Consulting for residential 
wastewater treatment solutions
wastewater treatment plants Aquatec VFL

Fast delivery times of 
WWTP

wastewater treatment plants Aquatec VFL Normal size trucks 
transport
wastewater treatment plants Aquatec VFL
Tested at PIA 
Testing Institute for 
Wastewater Technology 
in Aachen, Germany
wastewater treatment plants Aquatec VFL 230 V electricity connection
for residential WWTP
wastewater treatment plants Aquatec VFL Self supporting design
backfill with sorted material
wastewater treatment plants Aquatec VFL Stainless steel locking system
for WWTP
wastewater treatment plants Aquatec VFL
Remote control of
wastewater treatment plant
 

Our service regarding residential wastewater treatment plants

wastewater treatment plants Aquatec VFL PLACING of 
wastewater treatment plant
wastewater treatment plants Aquatec VFL START of
wastewater treatment plant
wastewater treatment plants Aquatec VFL SERVICE of
wastewater treatment plant

residential wastewater treatment plants Aquatec

 
Aquatec VFL service and maintenance of wastewater treatment plants
Simple installation of AT wastewater treatment plants
WWTPs of the type AT 6 to AT 20 are installed into a pit with a 15 cm thick reinforced concrete slab on the bottom, so that the upper edge of the WWTP tank overlaps about 5 cm above the terrain. If necessary, and if the design documentation requires it, the WWTP is to be concreted to the height specified by the project documentation. WWTP must be filled with water (to the outflow pipe level) before doing the backfill. Detailed instructions for installing of WWTPs are given in the operating instructions annexed. The Aquatec VFL technical team can take care of the installation.

Aquatec VFL service and maintenance of wastewater treatment plants
For the long lifetime of each process equipment, it is necessary to provide professional service. We therefore provide wastewater treatment plants maintenance and service throughout Slovakia:

Warranty service of wastewater treatment plants
Post-warranty service of wastewater treatment plants
Regular prepaid service of wastewater treatment plants
Emergency service of wastewater treatment plants

 
 
 
Advantages of Aquatec VFL wastewater treatment plants
 
Advantages of Aquatec VFL wastewater treatment plants Integrated retention chamber
for wastewater
Advantages of Aquatec VFL wastewater treatment plants Thickness of the tank wall is 8 mm and
is made by UV stable polypropylene
Advantages of Aquatec VFL wastewater treatment plants 10 years watertightness guarantee
Advantages of Aquatec VFL wastewater treatment plants First class materials used
for wastewater treatment plants
Advantages of Aquatec VFL wastewater treatment plants Stainless steel locking system for
every wastewater treatment plant
Advantages of Aquatec VFL wastewater treatment plants 100% money back guarantee
 
Accessories for Aquatec VFL wastewater treatment plants
 
Control units for Aquatec VFL wastewater treatment plants AQC BASIC or AQC BASIC GSM      Air blower for  wastewater treatment plants   Tank for the blower for wastewater treatment plants
Control units for Aquatec VFL wastewater treatment plants
AQC BASIC or AQC BASIC GSM
    Air blower for 
wastewater treatment plants
  Tank for the blower for
wastewater treatment plants
 

Evaluation of the German Testing Center PIA Aachen, where we tested several of our wastewater treatment plants.

Aquatec VFL wastewater treatment plans tested by PIA Aachen


Technical parameters:

TYPE Connected 
persons
[no.]
Tank
diameter x height

[mm]
Manhole
diameter
[mm]
Height and DN of 
inflow/outflow
[mm]
Usable
volume
[m3]
Daily inflow
[m3/day]
Weight
[kg]
Blower
[Liter]
Voltage
[V]
AT 6 2-5 1400x1800 1400* 1300/1150 -DN125 1,70 0,60 105 60 230
AT 8 6-7 1400x2200 1400* 1700/1500 -DN125 2,20 0,90 125 60 230
AT 10 8-9 1750x2200 1400 1500/1250 -DN125 3,10 1,20 195 80 230
AT 12 9-10 1750x2400 1400 1700/1500 -DN125 3,70 1,50 225 100 230
AT 15 11-15 2050x2200 1400 1700/1500 -DN150 5,10 1,95 330 120 230
AT 20 16-20 2050x2700 1400 2200/2000 -DN150 6,70 2,70 405 150 230

* according to selected solution 600 mm

AT6, AT8 and AT10 wastewater treatment plants from Aquatec VFL company. Size and shape comparison:

AT6, AT8 and AT10 wastewater treatment plants from Aquatec VFL company. Size and shape comparison:

Vertical Flow Labyrinth – VFL® - Treatment process
     
The technology uses a continuous-flow activated sludge process with biological nitrogen and phosphorus removal, which combines the following processes in a single tank:  mechanical pre-treatment, excess sludge collection, biological treatment using a low-loaded activated sludge process, separation of the treated water from activated sludge in the final clarification chamber, flow balancing of fluctuating inflow of wastewater in the retention chamber. The treatment process consists of several technological processes. Raw wastewater flows into the non-aerated activated sludge chamber with anaerobic and anoxic zones creating and admixture with the recirculated activated sludge, the mechanical pre-treatment of inflowing raw wastewater and the decomposition of coarse impurities, denitrification and accumulation of readily degradable organic contamination is taking place in the non-aerated activated sludge chamber, which is divided by inner partition walls to create a vertical flow labyrinth, where internal circulation is established. 
Furthermore, allowing the admixture flow gravitationally into the aerated activated sludge chamber with includes fine-bubble diffusors. In oxic conditions the biological degradation of organic contamination, nitrification and phosphorus uptake is taking place.  The activated sludge flows into the final clarification chamber, where the activated sludge is separated from the treated wastewater. The treated wastewater is discharged into a water flow, infiltrated or recycled and the separated activated sludge is recirculated by air-lifts.
A flow regulator is installed at the water level in the final clarification chamber which controls the outflow in order to maintain the water level between the normal and maximum level in the tank (integrated retention chamber).
The pressurized air is supplied by blowers for aeration of the activated sludge chamber and for recirculation via air-lift pumps. The recirculation and aeration is controlled by a microprocessor control unit which also enables the wastewater treatment plant to work in various modes depending on the loading.
čistiarne odpadových vôd Aquatec VFL -  Sewage water treatment systems
 

1 – Anaerobic and anoxic zones with „Vertical Flow Labyrinth“
2 – Oxic chamber
3 – Final clarification chamber
4 – Integrated retention chamber
5 – Internal recirculation
6 – Recirculation of sludge
7 – Fine-bubble diffusor
8 – Flow regulator

The technology Vertical Flow Labyrinth – VFL®, used in the biological reactor, is protected internationally by patent. The purification technology ensures the high quality of purified water, low investment and operation costs.

European Union
The AT wastewater treatment plant meet the requirements for the resistance of inflowing sewage water abruptly. Ensuring the homogeneous operation of the wastewater treatment plant in the event of abrupt outpour of high volume of water (e.g. bathtub, washing machine, etc.). The wastewater treatment plant main problem is respect to the discharge of the activated sludge upon every abrupt inflow resulting in solving this issue.

 

To page top